اینورتر سه فاز 55 کيلووات اشنایدر ATV212HD55N4

variable speed drive, Altivar 212, 55kW, 75hp, 480V, 3 phases, with EMC, IP21

اینورتر سه فاز 55 کيلووات اشنایدر ATV212HD55N4

اینورتر سه فاز 55 کيلووات اشنایدر ATV212HD55N4

Main
Device short name ATV212
Product destination Asynchronous motors
Phase 3 phase
Motor power kW 55 kW
Maximum Horse Power Rating 75 hp
Supply voltage limits 323…528 V
Supply frequency 50…60 Hz – 5…5 %
Line current 102.7 A 380 V
89 A 480 V
Range of Product Altivar 212
Product or Component Type Variable speed drive
Product Specific Application Pumps and fans in HVAC
Communication Port Protocol METASYS N2
BACnet
LonWorks
APOGEE FLN
Modbus
[Us] rated supply voltage 380…480 V – 15…10 %
EMC filter Class C2 EMC filter integrated
IP degree of protection IP21
Complementary
Apparent power 76.3 kVA 380 V
Continuous output current 116 A 380 V
116 A 460 V
Maximum transient current 127.6 A 60 s
Speed drive output frequency 0.5…200 Hz
Speed range 1…10
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn
Local signalling for DC bus energized 1 LED (red)
Output voltage <= power supply voltage
Isolation Electrical between power and control
Type of cable Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
Electrical connection VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 0.004 in² (2.5 mm²) / AWG 14
L1/R, L2/S, L3/T terminal 0.2 in² (150 mm²) 300 kcmil)
Tightening torque 5.3 lbf.in (0.6 N.m) VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
362.9 lbf.in (41 N.m), 360 lb.in L1/R, L2/S, L3/T)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection
Internal supply 24 V DC 21…27 V), <200 A overload and short-circuit protection
Sampling duration 2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete
2 ms +/- 0.5 ms RES discrete
3.5 ms +/- 0.5 ms VIA analog
22 ms +/- 0.5 ms VIB analog
Response time FM 2 ms +/- 0.5 ms analog
FLA, FLC 7 ms +/- 0.5 ms discrete
FLB, FLC 7 ms +/- 0.5 ms discrete
RY, RC 7 ms +/- 0.5 ms discrete
Accuracy +/- 0.6 % VIA) for a temperature variation 60 °C
+/- 0.6 % VIB) for a temperature variation 60 °C
+/- 1 % FM) for a temperature variation 60 °C
Linearity error VIA +/- 0.15 % of maximum value input
VIB +/- 0.15 % of maximum value input
FM +/- 0.2 % output
Analogue output type FM switch-configurable voltage 0…10 V DC 7620 Ohm 10 bits
FM switch-configurable current 0…20 mA 970 Ohm 10 bits
Discrete output type Configurable relay logic FLA, FLC) NO – 100000 cycles
Configurable relay logic FLB, FLC) NC – 100000 cycles
Configurable relay logic RY, RC) NO – 100000 cycles
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current 5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R)
5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R)
2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R)
2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R)
Discrete input type F programmable 24 V DC level 1 PLC 4700 Ohm
R programmable 24 V DC level 1 PLC 4700 Ohm
RES programmable 24 V DC level 1 PLC 4700 Ohm
Discrete input logic Positive logic (source) F, R, RES), <= 5 V, >= 11 V
Negative logic (sink) F, R, RES), >= 16 V, <= 10 V
Dielectric strength 3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Insulation resistance >= 1 mOhm 500 V DC for 1 minute
Frequency resolution Display unit 0.1 Hz
Analog input 0.024/50 Hz
Communication Service Time out setting from 0.1 to 100 s
Write multiple registers (16) 2 words maximum
Write single register (06)
Read holding registers (03) 2 words maximum
Read device identification (43)
Monitoring inhibitable
Option card Communication card LonWorks
Power dissipation in W 1455 W
air flow 131560.04 Gal/hr(US) (498 m3/h)
Functionality Mid
Specific application HVAC
Variable speed drive application selection Building – HVAC compressor for scroll
Building – HVAC fan
Building – HVAC pump
Motor power range AC-3 55…100 kW 380…440 V 3 phase
55…100 kW 480…500 V 3 phase
Motor starter type Variable speed drive
Discrete output number 2
Analogue input number 2
Analogue input type VIA switch-configurable voltage 0…10 V DC 24 V max 30000 Ohm 10 bits
VIB configurable voltage 0…10 V DC 24 V max 30000 Ohm 10 bits
VIB configurable PTC probe 0…6 probes 1500 Ohm
VIA switch-configurable current 0…20 mA 250 Ohm 10 bits
Analogue output number 1
Physical interface 2-wire RS 485
Connector Type 1 open style
1 RJ45
Transmission Rate 9600 bps or 19200 bps
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, 1 stop, odd even or no configurable parity
Type of polarization No impedance
Asynchronous motor control profile Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Flux vector control without sensor, standard
Voltage/frequency ratio, 5 points
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 2 points
Torque accuracy +/- 15 %
Transient overtorque 120 % of nominal motor torque +/- 10 % 60 s
Acceleration and deceleration ramps Automatic based on the load
Linear adjustable separately from 0.01 to 3200 s
Motor slip compensation Adjustable
Automatic whatever the load
Not available in voltage/frequency ratio motor control
Switching frequency 6…16 kHz adjustable
8…16 kHz with derating factor
Nominal switching frequency 8 kHz
Braking to standstill By DC injection
Network Frequency 47.5…63 Hz
Prospective line Isc 22 kA
Protection type Overheating protection drive
Thermal power stage drive
Short-circuit between motor phases drive
Input phase breaks drive
Overcurrent between output phases and earth drive
Overvoltages on the DC bus drive
Break on the control circuit drive
Against exceeding limit speed drive
Line supply overvoltage and undervoltage drive
Line supply undervoltage drive
Against input phase loss drive
Thermal protection motor
Motor phase break motor
With PTC probes motor
Width 12.6 in (320 mm)
Height 24.8 in (630 mm)
Depth 11.4 in (290 mm)
Environment
Pollution degree 3 IEC 61800-5-1
IP degree of protection IP20 on upper part without blanking plate on cover IEC 61800-5-1
IP20 on upper part without blanking plate on cover IEC 60529
IP21 IEC 61800-5-1
IP21 IEC 60529
IP41 on upper part IEC 61800-5-1
IP41 on upper part IEC 60529
Vibration resistance 1.5 mm (f= 3…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8
Shock resistance 15 gn 11 ms IEC 60068-2-27
Environmental characteristic Classes 3C1 conforming to IEC 60721-3-3
Classes 3S2 conforming to IEC 60721-3-3
Noise level 63.7 dB 86/188/EEC
Operating altitude 3280.84…9842.52 ft (1000…3000 m) limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m
<= 3280.84 ft (1000 m) without derating
Relative humidity 5…95 % without condensation IEC 60068-2-3
5…95 % without dripping water IEC 60068-2-3
Ambient air temperature for operation 14…104 °F (-10…40 °C) (without derating)
104…122 °F (40…50 °C) (with derating factor)
Operating position Vertical +/- 10 degree
Product Certifications C-tick
UL
CSA
NOM 117
Marking CE
Standards IEC 61800-3 environments 1 category C1
IEC 61800-3 environments 1 category C3
IEC 61800-5-1
IEC 61800-3
IEC 61800-3 environments 2 category C1
IEC 61800-3
IEC 61800-3 environments 1 category C2
EN 55011 class A group 1
IEC 61800-3 environments 1 category C1
IEC 61800-3 environments 2 category C3
IEC 61800-3 environments 1 category C2
IEC 61800-3 environments 2 category C3
IEC 61800-3 environments 2 category C2
UL Type 1
IEC 61800-3 category C2
IEC 61800-3 category C3
IEC 61800-5-1
EN 61800-3 category C3
IEC 61800-3 environments 2 category C2
IEC 61800-3 environments 1 category C3
IEC 61800-3 category C2
IEC 61800-3 environments 2 category C1
Assembly style With heat sink
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Regulation loop Adjustable PI regulator
Ambient Air Temperature for Storage -13…158 °F (-25…70 °C)
Ordering and shipping details
Category US1CP4D22158
Discount Schedule CP4D
GTIN 3606480322587
Returnability Yes
Country of origin CN
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 18.50 in (47 cm)
Package 1 Width 19.69 in (50 cm)
Package 1 Length 30.31 in (77 cm)
Package 1 Weight 93.7 lb(US) (42.5 kg)
Contractual warranty
Warranty 18 months

توضیحات تکمیلی

نوع:

سه فاز

توان موتور:

55KW کاربرد سبک

هیت سینک:

دارد

فیلتر EMC:

دارد

پنل گرافیکی:

دارد

پرتکل های ارتباطی:

METASYS N2
BACnet
LonWorks
APOGEE FLN
Modbus

پورت ارتباطی:

RJ45

نرم افزار سازگار:

SoMove

درجه حفاظت:

IP20

کاربرد موتور:

کنترل موتور های آسنکرون

کاتالوگ

https://pishrosanatnovin.com/wp-content/uploads/2025/04/Schneider-Electric_Altivar-212-Variable-Frequency-Drive-VFD_ATV212HD55N4.pdf

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “اینورتر سه فاز 55 کيلووات اشنایدر ATV212HD55N4”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

حمل و نقل

همه زمان های تخمینی ارسال علاوه بر زمان های تکمیل است، برای سفارش هایی که قبل از ساعت ۶:۳۰ بعدازظهر انجام می شوند، یک روز کاری بعدی تحویل می دهیم. از شنبه تا پنجشنبه. سفارش هایی که بعد از این ارسال می شوند، ظرف دو روز کاری تحویل داده می شوند. .

Shipping
  • ارسال رایگان بالای 50 میلیون تومان
  • ارسال در سریع ترین زمان با کم ترین هزینه
  • تهران خرید بالای 20 میلیون ارسال رایگان
  • ارسال با پست ، تیپاکس ، باربری و ترمینال

    بازگشت و پرداخت

    ما یک خط مشی بازگشت ۱۴ روزه داریم، به این معنی که شما ۱۴ روز پس از دریافت کالای خود فرصت دارید تا درخواست بازگشت بدهید، برای واجد شرایط بودن برای بازگرداندن، کالای شما باید در همان شرایطی باشد که آن را دریافت کرده اید، استفاده نشده و در اصل آن باشد. بسته بندی. همچنین به تأیید سفارش، شماره سفارش یا مدرک خرید نیاز دارید. پس از دریافت و بازرسی بازگشت شما، به شما اطلاع می دهیم و به شما اطلاع می دهیم که آیا بازپرداخت تأیید شده است یا خیر. در صورت تایید، به صورت خودکار از طریق روش پرداخت اصلی به شما بازپرداخت می شود. لطفاً به یاد داشته باشید که پردازش و ارسال بازپرداخت بانک یا شرکت کارت اعتباری شما نیز ممکن است کمی طول بکشد.برای درخواست بازگشت باید دلیل موجه در مورد جنس یا عدم تایید و یا مغایرت کالای ارسالی با پیش فاکتور ارسالی داشته باشین.

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “اینورتر سه فاز 55 کيلووات اشنایدر ATV212HD55N4”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *