Range | TeSys |
---|---|
product name | TeSys LRG |
Product or component type | Electronic thermal overload relay |
Device short name | LR9G |
Relay application | Motor protection |
network type | AC |
Thermal overload class | Class 5E…30E conforming to IEC 60947-4-1 |
Thermal protection adjustment range | 160…630 A |
Network frequency | 30…60 Hz 100 Hz |
---|---|
overvoltage category | III |
Tripping threshold | 1.125 +/- 0.07 In conforming to IEC 60947-4-1 |
Protection type | Ground fault protection – tripping time adjustment: 0…1 s – for alarm circuit conforming to IEC 60947-4-1 Ground fault protection – tripping time adjustment: 0…1 s – for alarm circuit conforming to UL 60947-4-1 Phase loss – tripping time adjustment: 0…4 s – for alarm circuit Phase imbalance – tripping time adjustment: 0…5 s – for alarm circuit conforming to IEC 60947-4-1 Phase imbalance – tripping time adjustment: 0…5 s – for alarm circuit conforming to UL 60947-4-1 |
Local signalling | LED Trip indicator |
Contacts type and composition | 1 NO + 1 NC |
[Ith] conventional free air thermal current | 5 A |
[Uc] control circuit voltage | 24…500 V AC 50/60 Hz 24…250 V DC |
[Ue] rated operational voltage | 1000 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 8 kV |
Reset | Automatic reset Manual |
Mechanical durability | 7000 cycles |
Surge withstand | 4 kV |
Electromagnetic compatibility | EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference – test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47 |
Connections – terminals | Power circuit: bar – busbar cross section: 50 x 10 mm Power circuit: lugs-ring terminals 1 300 mm² Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end Control circuit: push-in 2 0.5…1.0 mm² with cable end |
Tightening torque | 58 N.m |
Mounting support | Direct on contactor Plate |
Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ UL 60335-1 |
Product certifications | CB Scheme CCC cULus UKCA ATEX EU-RO-MR by DNV-GL EAC |
IP degree of protection | IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106 |
---|---|
Protective treatment | TH |
Ambient air temperature for operation | -25…60 °C |
Ambient air temperature for storage | -60…80 °C |
Permissible ambient air temperature around the device | -40…60 °C at Uc |
Adjustment of dial setting | -25…60 °C |
Mechanical robustness | Vibrations 5…300 Hz 6 gn contactor open Shocks 15 gn 11 ms contactor closed |
Height | 148 mm |
Width | 211 mm |
Depth | 186 mm |
Net weight | 2.9 kg |
Colour | Dark grey |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 30.000 cm |
Package 1 Width | 30.000 cm |
Package 1 Length | 40.000 cm |
Package 1 Weight | 4.700 kg |
نقد و بررسیها