اینورتر سه فاز 110 کيلووات اشنایدر ATV61HC11N4

اینورتر سه فاز 110 کيلووات اشنایدر ATV61HC11N4

Main
Range of Product Altivar 61
Product or Component Type Variable speed drive
Product Specific Application Pumping and ventilation machine
Component name ATV61
Motor power kW 110 kW, 3 phase 380…480 V
Maximum Horse Power Rating 150 hp, 3 phase 380…480 V
power supply voltage 380…480 V – 15…10 %
supply number of phases 3 phase
Line current 168 A 480 V 3 phase 110 kW / 150 hp
202 A 380 V 3 phase 110 kW / 150 hp
EMC filter Level 3 EMC filter
Assembly style With heat sink
Apparent power 133 kVA 380 V 3 phase 110 kW / 150 hp
maximum prospective line Isc 35 kA 3 phase
Maximum transient current 258 A 60 s, 3 phase
Nominal switching frequency 2.5 kHz
Switching frequency 2…8 kHz adjustable
2.5…8 kHz with derating factor
asynchronous motor control Voltage/frequency ratio, 5 points
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 2 points
Flux vector control without sensor, standard
Synchronous motor control profile Vector control without sensor, standard
Communication Port Protocol Modbus
CANopen
Type of polarization No impedance Modbus
Option card Communication card APOGEE FLN
Communication card BACnet
Communication card CC-Link
Controller inside programmable card
Communication card DeviceNet
Communication card EtherNet/IP
Communication card Fipio
I/O extension card
Communication card Interbus-S
Communication card LonWorks
Communication card METASYS N2
Communication card Modbus Plus
Communication card Modbus TCP
Communication card Modbus/Uni-Telway
Multi-pump card
Communication card Profibus DP
Communication card Profibus DP V1
Complementary
Product destination Asynchronous motors
Synchronous motors
power supply voltage limits 323…528 V
power supply frequency 50…60 Hz – 5…5 %
power supply frequency limits 47.5…63 Hz
Continuous output current 215 A 2.5 kHz, 380 V – 3 phase
215 A 2.5 kHz, 460 V – 3 phase
Output frequency 0.1…500 Hz
Speed range 1…100 in open-loop mode, without speed feedback
Speed accuracy +/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback
Torque accuracy +/- 15 % in open-loop mode, without speed feedback
Transient overtorque 130 % of nominal motor torque +/- 10 % 60 s
Braking torque <= 125 % with braking resistor
30 % without braking resistor
Regulation loop Frequency PI regulator
Motor slip compensation Adjustable
Not available in voltage/frequency ratio (2 or 5 points)
Automatic whatever the load
Can be suppressed
diagnostic for drive voltage 1 LED (red)
output voltage <= power supply voltage
electrical isolation Between power and control terminals
type of cable for mounting in an enclosure With an IP21 or an IP31 kit 3 IEC cable 104 °F (40 °C), copper 70 °C / PVC
With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR
Electrical connection Terminal 2.5 mm² / AWG 14 AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR)
Terminal 2 x 100 mm² / 2 x 250 kcmil L1/R, L2/S, L3/T, U/T1, V/T2, W/T3)
Terminal 60 mm² / 250 kcmil PA, PB)
Terminal 2 x 100 mm² / 2 x 250 kcmil PC/-, PO, PA/+)
Tightening torque 5.3 lbf.in (0.6 N.m) AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1…LI6, PWR)
212.4 lbf.in (24 N.m), 212 lb.in L1/R, L2/S, L3/T, U/T1, V/T2, W/T3)
362.9 lbf.in (41 N.m), 360 lb.in PC/-, PO, PA/+)
106.2 lbf.in (12 N.m), 106 lb.in PA, PB)
Supply Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC, +/- 5 %, <10 mA overload and short-circuit protection
Internal supply 24 V DC 21…27 V), <200 mA overload and short-circuit protection
External supply 24 V DC 19…30 V)
Analogue input number 2
Analogue input type AI1-/Al1+ bipolar differential voltage +/- 10 V DC 24 V max 11 bits + sign
AI2 software-configurable current 0…20 mA 242 Ohm 11 bits
AI2 software-configurable voltage 0…10 V DC 24 V max 30000 Ohm 11 bits
sampling time 2 ms +/- 0.5 ms AI1-/Al1+) – analog input
2 ms +/- 0.5 ms Al2) – analog input
2 ms +/- 0.5 ms AO1) – analog output
2 ms +/- 0.5 ms LI1…LI5) – discrete input
2 ms +/- 0.5 ms LI6)if configured as logic input – discrete input
absolute accuracy precision +/- 0.6 % AI1-/Al1+) for a temperature variation 60 °C
+/- 0.6 % AI2) for a temperature variation 60 °C
+/- 1 % AO1) for a temperature variation 60 °C
Linearity error +/- 0.15 % of maximum value AI1-/Al1+)
+/- 0.15 % of maximum value AI2)
+/- 0.2 % AO1)
Analogue output number 1
Analogue output type AO1 software-configurable current 0…20 mA 500 Ohm 10 bits
AO1 software-configurable voltage 0…10 V DC 470 Ohm 10 bits
AO1 software-configurable logic output 10 V, 20 mA
Discrete output number 2
Discrete output type Configurable relay logic R1A, R1B, R1C) NO/NC – 100000 cycles
Configurable relay logic R2A, R2B) NO – 100000 cycles
maximum response time <= 100 ms in STO (Safe Torque Off)
R1A, R1B, R1C <= 7 ms +/- 0.5 ms
R2A, R2B <= 7 ms +/- 0.5 ms
Minimum switching current 3 mA 24 V DC configurable relay logic
Maximum switching current R1, R2 2 A 250 V AC inductive, cos phi = 0.4 7 ms
R1, R2 2 A 30 V DC inductive, cos phi = 0.4 7 ms
R1, R2 5 A 250 V AC resistive, cos phi = 1 0 ms
R1, R2 5 A 30 V DC resistive, cos phi = 1 0 ms
Discrete input number 7
Discrete input type Programmable LI1…LI5) 24 V DC <= 30 V)level 1 PLC – 3500 Ohm
Switch-configurable LI6) 24 V DC <= 30 V)level 1 PLC – 3500 Ohm
Switch-configurable PTC probe LI6)0…6 – 1500 Ohm
Safety input PWR) 24 V DC <= 30 V) – 1500 Ohm
Discrete input logic Negative logic (sink) LI1…LI5), > 16 V, < 10 V
Positive logic (source) LI1…LI5), < 5 V, > 11 V
Negative logic (sink) LI6)if configured as logic input, > 16 V, < 10 V
Positive logic (source) LI6)if configured as logic input, < 5 V, > 11 V
Acceleration and deceleration ramps Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
Braking to standstill By DC injection
Protection type Against exceeding limit speed drive
Against input phase loss drive
Break on the control circuit drive
Input phase breaks drive
Line supply overvoltage drive
Line supply undervoltage drive
Overcurrent between output phases and earth drive
Overheating protection drive
Overvoltages on the DC bus drive
Power removal drive
Short-circuit between motor phases drive
Thermal protection drive
Motor phase break motor
Power removal motor
Thermal protection motor
Insulation resistance > 1 mOhm 500 V DC for 1 minute to earth
Frequency resolution Analog input 0.024/50 Hz
Display unit 0.1 Hz
Connector type 1 RJ45 on front face)Modbus
1 RJ45 on terminal)Modbus
Male SUB-D 9 on RJ45CANopen
Physical interface 2-wire RS 485 Modbus
Transmission frame RTU Modbus
Transmission rate 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps Modbus on terminal
9600 bps, 19200 bps Modbus on front face
20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps CANopen
Data format 8 bits, 1 stop, even parity Modbus on front face
8 bits, odd even or no configurable parity Modbus on terminal
Number of addresses 1…127 CANopen
1…247 Modbus
Method of access Slave CANopen
Marking CE
Operating position Vertical +/- 10 degree
Net Weight 185.2 lb(US) (84 kg)
Width 12.6 in (320 mm)
Height 36.2 in (920 mm)
Depth 14.8 in (377 mm)
Environment
Noise level 60.5 dB 86/188/EEC
Dielectric strength 3535 V DC between earth and power terminals
5092 V DC between control and power terminals
Electromagnetic compatibility Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Standards IEC 60721-3-3 class 3C2
EN 61800-3 environments 2 category C3
EN/IEC 61800-5-1
EN 61800-3 environments 1 category C3
EN 55011 class A group 2
UL Type 1
EN/IEC 61800-3
Product Certifications GOST
CSA
C-tick
NOM 117
DNV
UL
Pollution degree 3 EN/IEC 61800-5-1
3 UL 840
degree of proctection IP41 on upper part EN/IEC 60529
IP41 on upper part EN/IEC 61800-5-1
IP54 on lower part EN/IEC 60529
IP54 on lower part EN/IEC 61800-5-1
IP00 EN/IEC 60529
IP00 EN/IEC 61800-5-1
IP30 on side parts EN/IEC 60529
IP30 on side parts EN/IEC 61800-5-1
IP30 on the front panel EN/IEC 60529
IP30 on the front panel EN/IEC 61800-5-1
Vibration resistance 0.6 gn (f= 10…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f= 3…10 Hz) conforming to EN/IEC 60068-2-6
Shock resistance 7 gn 11 ms EN/IEC 60068-2-27
Relative humidity 5…95 % without condensation IEC 60068-2-3
5…95 % without dripping water IEC 60068-2-3
Ambient air temperature for operation 14…113 °F (-10…45 °C) (without derating)
113…140 °F (45…60 °C) (with derating factor)
Ambient Air Temperature for Storage -13…158 °F (-25…70 °C)
Operating altitude <= 3280.84 ft (1000 m) without derating
3280.84…9842.52 ft (1000…3000 m) with current derating 1 % per 100 m
Ordering and shipping details
Category US1CP4C22138
Discount Schedule CP4C
GTIN 3389118080614
Returnability No
Country of origin IN
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 20.87 in (53.000 cm)
Package 1 Width 16.14 in (41.000 cm)
Package 1 Length 48.23 in (122.500 cm)
Package 1 Weight 253.532 lb(US) (115.000 kg)
Contractual warranty
Warranty 18 months

توضیحات تکمیلی

نوع:

سه فاز

توان موتور:

110KW کاربرد سبک

هیت سینک:

دارد

فیلتر EMC:

دارد

پنل گرافیکی:

دارد

پرتکل ارتباطی:

Modbus , CANopen

پورت ارتباطی:

RJ45

نرم افزار سازگار:

SoMove

درجه حفاظت:

IP20

کاربرد موتور:

کنترل موتور های سنکرون و آسنکرون

محصول جایگزین:

ATV630

کاتالوگ

https://pishrosanatnovin.com/wp-content/uploads/2025/04/Schneider-Electric_Altivar-61-Variable-Frequency-Drives-VFD_ATV61HC11N4.pdf

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “اینورتر سه فاز 110 کيلووات اشنایدر ATV61HC11N4”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

حمل و نقل

همه زمان های تخمینی ارسال علاوه بر زمان های تکمیل است، برای سفارش هایی که قبل از ساعت ۶:۳۰ بعدازظهر انجام می شوند، یک روز کاری بعدی تحویل می دهیم. از شنبه تا پنجشنبه. سفارش هایی که بعد از این ارسال می شوند، ظرف دو روز کاری تحویل داده می شوند. .

Shipping
  • ارسال رایگان بالای 50 میلیون تومان
  • ارسال در سریع ترین زمان با کم ترین هزینه
  • تهران خرید بالای 20 میلیون ارسال رایگان
  • ارسال با پست ، تیپاکس ، باربری و ترمینال

    بازگشت و پرداخت

    ما یک خط مشی بازگشت ۱۴ روزه داریم، به این معنی که شما ۱۴ روز پس از دریافت کالای خود فرصت دارید تا درخواست بازگشت بدهید، برای واجد شرایط بودن برای بازگرداندن، کالای شما باید در همان شرایطی باشد که آن را دریافت کرده اید، استفاده نشده و در اصل آن باشد. بسته بندی. همچنین به تأیید سفارش، شماره سفارش یا مدرک خرید نیاز دارید. پس از دریافت و بازرسی بازگشت شما، به شما اطلاع می دهیم و به شما اطلاع می دهیم که آیا بازپرداخت تأیید شده است یا خیر. در صورت تایید، به صورت خودکار از طریق روش پرداخت اصلی به شما بازپرداخت می شود. لطفاً به یاد داشته باشید که پردازش و ارسال بازپرداخت بانک یا شرکت کارت اعتباری شما نیز ممکن است کمی طول بکشد.برای درخواست بازگشت باید دلیل موجه در مورد جنس یا عدم تایید و یا مغایرت کالای ارسالی با پیش فاکتور ارسالی داشته باشین.

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “اینورتر سه فاز 110 کيلووات اشنایدر ATV61HC11N4”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *