کنتاکتور 95 آمپر 24 ولت AC اشنایدر LC1D95B7

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 95A/1000V AC-3/AC-3e (45kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts, power connections by screw terminals and control by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh). Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.55 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

کنتاکتور 95 آمپر 24 ولت AC اشنایدر LC1D95B7

کنتاکتور 95 آمپر 24 ولت AC اشنایدر LC1D95B7

Main
Range TeSys
Range of Product TeSys Deca
Product or Component Type Contactor
Device short name LC1D
Contactor application Motor control
Resistive load
Utilisation category AC-3
AC-3e
AC-4
AC-1
Poles description 3P
[Ue] rated operational voltage Power circuit <= 690 V AC 25…400 Hz
[Ie] rated operational current 95 A (at <140 °F (60 °C)) at <= 440 V AC-3 for power circuit
125 A (at <140 °F (60 °C)) at <= 690 V AC-1 for power circuit
95 A (at <140 °F (60 °C)) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage 24 V AC 50/60 Hz
Complementary
Motor power kW 25 kW at 220…230 V AC 50 Hz (AC-3)
45 kW at 380…400 V AC 50 Hz (AC-3)
45 kW at 415…440 V AC 50 Hz (AC-3)
55 kW at 500 V AC 50 Hz (AC-3)
45 kW at 660…690 V AC 50 Hz (AC-3)
15 kW at 400 V AC 50 Hz (AC-4)
25 kW at 220…230 V AC 50 Hz (AC-3e)
45 kW at 380…400 V AC 50 Hz (AC-3e)
45 kW at 415…440 V AC 50 Hz (AC-3e)
55 kW at 500 V AC 50 Hz (AC-3e)
45 kW at 660…690 V AC 50 Hz (AC-3e)
Maximum Horse Power Rating 7.5 hp at 120 V AC 60 Hz for 1 phase motors
15 hp at 230/240 V AC 60 Hz for 1 phase motors
30 hp at 200/208 V AC 60 Hz for 3 phase motors
30 hp at 230/240 V AC 60 Hz for 3 phase motors
60 hp at 460/480 V AC 60 Hz for 3 phase motors
60 hp at 575/600 V AC 60 Hz for 3 phase motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 140 °F (60 °C)) for signalling circuit
125 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity 1100 A at 440 V AC for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 1100 A 104 °F (40 °C) – 1 s for power circuit
800 A 104 °F (40 °C) – 10 s for power circuit
400 A 104 °F (40 °C) – 1 min for power circuit
135 A 104 °F (40 °C) – 10 min for power circuit
140 A – 100 ms for signalling circuit
120 A – 500 ms for signalling circuit
100 A – 1 s for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.8 mOhm – Ith 125 A 50 Hz for power circuit
Power dissipation per pole 12.5 W AC-1
7.2 W AC-3
7.2 W AC-3e
[Ui] rated insulation voltage Power circuit 1000 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
overvoltage category III
pollution degree 3
[Uimp] rated impulse withstand voltage 8 kV IEC 60947
Safety reliability level B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1
B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability 4 Mcycles
Electrical durability 1.2 Mcycles 95 A AC-3
1.3 Mcycles 125 A AC-1
1.2 Mcycles 95 A AC-3e
Control circuit type AC 50/60 Hz standard
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.8…1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 50 Hz
0.85…1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 60 Hz
0.3…0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz
1…1.1 Uc (131…158 °F (55…70 °C)):operational AC 50/60 Hz
Inrush power in VA 245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA 26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation 6…10 W at 50/60 Hz
Operating time 20…35 ms closing
6…20 ms opening
Maximum operating rate 3600 cyc/h at 60 °C
Connections – terminals Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible without cable end
Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: flexible without cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible with cable end
Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) – cable stiffness: flexible with cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: solid without cable end
Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: solid without cable end
Tightening torque Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2
Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm
Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm)
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency 25…400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support Plate
Rail
Environment
Standards EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
CSA C22.2 No 14
UL 60947-4-1
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
IEC 60335-1:Clause 30.2
Product Certifications CCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC
IP degree of protection IP20 front face IEC 60529
Protective treatment THIEC 60068-2-30
Climatic withstand IACS E10 exposure to damp heat
Permissible ambient air temperature around the device -40…140 °F (-40…60 °C)
140…158 °F (60…70 °C) with derating
Operating altitude 0…9842.52 ft (0…3000 m)
Fire resistance 1562 °F (850 °C) IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open 2 Gn, 5…300 Hz)
Shocks contactor open 8 Gn for 11 ms)
Vibrations contactor closed 3 Gn, 5…300 Hz)
Shocks contactor closed 10 Gn for 11 ms)
Height 5.0000000000 in (127 mm)
Width 3.3 in (85 mm)
Depth 5.1 in (130 mm)
Net Weight 3.55 lb(US) (1.61 kg)
Ordering and shipping details
Category US10I1222359
Discount Schedule 0I12
GTIN 3389110450651
Returnability Yes
Country of origin CZ
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 3.74 in (9.5 cm)
Package 1 Width 5.31 in (13.5 cm)
Package 1 Length 5.51 in (14 cm)
Package 1 Weight 3.448 lb(US) (1.564 kg)
Unit Type of Package 2 S02
Number of Units in Package 2 5
Package 2 Height 5.91 in (15 cm)
Package 2 Width 11.81 in (30 cm)
Package 2 Length 15.75 in (40 cm)
Package 2 Weight 18.243 lb(US) (8.275 kg)
Unit Type of Package 3 P06
Number of Units in Package 3 80
Package 3 Height 31.50 in (80 cm)
Package 3 Width 31.50 in (80 cm)
Package 3 Length 23.62 in (60 cm)
Package 3 Weight 310.6 lb(US) (140.9 kg)
Contractual warranty
Warranty 18 months

توضیحات تکمیلی

رنج جریان

95A

ولتاژ تغذیه بوبین

24VAC

کد فنی بوبین

LX1D6B5

توان

45kW در 220/380V

کنتاکت کمکی

1NO+1NC

اتصالات

ترمینال پیچی

تعداد پل

3P

نوع کنتاکتور

AC

کاتالوگ

https://pishrosanatnovin.com/wp-content/uploads/2025/01/Schneider-Electric_TeSys-Deca-Contactors_LC1D95B7.pdf

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “کنتاکتور 95 آمپر 24 ولت AC اشنایدر LC1D95B7”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

حمل و نقل

همه زمان های تخمینی ارسال علاوه بر زمان های تکمیل است، برای سفارش هایی که قبل از ساعت ۶:۳۰ بعدازظهر انجام می شوند، یک روز کاری بعدی تحویل می دهیم. از شنبه تا پنجشنبه. سفارش هایی که بعد از این ارسال می شوند، ظرف دو روز کاری تحویل داده می شوند. .

Shipping
  • ارسال رایگان بالای 50 میلیون تومان
  • ارسال در سریع ترین زمان با کم ترین هزینه
  • تهران خرید بالای 20 میلیون ارسال رایگان
  • ارسال با پست ، تیپاکس ، باربری و ترمینال

    بازگشت و پرداخت

    ما یک خط مشی بازگشت ۱۴ روزه داریم، به این معنی که شما ۱۴ روز پس از دریافت کالای خود فرصت دارید تا درخواست بازگشت بدهید، برای واجد شرایط بودن برای بازگرداندن، کالای شما باید در همان شرایطی باشد که آن را دریافت کرده اید، استفاده نشده و در اصل آن باشد. بسته بندی. همچنین به تأیید سفارش، شماره سفارش یا مدرک خرید نیاز دارید. پس از دریافت و بازرسی بازگشت شما، به شما اطلاع می دهیم و به شما اطلاع می دهیم که آیا بازپرداخت تأیید شده است یا خیر. در صورت تایید، به صورت خودکار از طریق روش پرداخت اصلی به شما بازپرداخت می شود. لطفاً به یاد داشته باشید که پردازش و ارسال بازپرداخت بانک یا شرکت کارت اعتباری شما نیز ممکن است کمی طول بکشد.برای درخواست بازگشت باید دلیل موجه در مورد جنس یا عدم تایید و یا مغایرت کالای ارسالی با پیش فاکتور ارسالی داشته باشین.

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “کنتاکتور 95 آمپر 24 ولت AC اشنایدر LC1D95B7”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *