اینورتر تک فاز 0.75 کيلووات اشنایدر ATV312H075M2
اینورتر تک فاز 0.75 کيلووات اشنایدر ATV312H075M2
Range of product | Altivar 312 |
---|---|
Product or component type | Variable speed drive |
Product destination | Asynchronous motors |
Product specific application | Simple machine |
Assembly style | With heat sink |
Component name | ATV312 |
Motor power kW | 0.75 kW |
Motor power hp | 1 hp |
[Us] rated supply voltage | 200…240 V – 15…10 % |
Supply frequency | 50…60 Hz – 5…5 % |
Network number of phases | Single phase |
Line current | 8.9 A at 200 V, Isc = 1 kA 7.5 A at 240 V |
EMC filter | Integrated |
Apparent power | 1.8 kVA |
Maximum transient current | 7.2 A for 60 s |
Power dissipation in W | 60 W at nominal load |
Speed range | 1…50 |
Asynchronous motor control profile | Factory set : constant torque Sensorless flux vector control with PWM type motor control signal |
Electrical connection | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1…LI6 terminal 2.5 mm² AWG 14 L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 2.5 mm² AWG 14 |
Supply | Internal supply for logic inputs: 19…30 V 100 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (2.2 to 10 kOhm): 10…10.8 V 10 mA, protection type: overload and short-circuit protection |
Communication port protocol | Modbus CANopen |
IP degree of protection | IP20 on upper part without cover plate IP21 on connection terminals IP31 on upper part IP41 on upper part |
Option card | Communication card for CANopen daisy chain Communication card for DeviceNet Communication card for Fipio Communication card for Modbus TCP Communication card for Profibus DP |
Supply voltage limits | 170…264 V |
---|---|
Prospective line Isc | 1 kA |
Continuous output current | 4.8 A at 4 kHz |
Output frequency | 0…500 Hz |
Nominal switching frequency | 4 kHz |
Switching frequency | 2…16 kHz adjustable |
Transient overtorque | 170…200 % of nominal motor torque |
Braking torque | 150 % during 60 s with braking resistor 100 % with braking resistor continuously 150 % without braking resistor |
Regulation loop | Frequency PI regulator |
Motor slip compensation | Suppressable Adjustable Automatic whatever the load |
Output voltage | <= power supply voltage |
Tightening torque | Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1…LI6: 0.6 N.m L1, L2, L3, U, V, W, PA, PB, PA/+, PC/-: 0.8 N.m |
Insulation | Electrical between power and control |
Analogue input number | 3 |
Analogue input type | AI1 configurable voltage 0…10 V, input voltage 30 V max, impedance: 30000 Ohm AI2 configurable voltage +/- 10 V, input voltage 30 V max, impedance: 30000 Ohm AI3 configurable current 0…20 mA, impedance: 250 Ohm |
Sampling duration | AI1, AI2, AI3: 8 ms analog LI1…LI6: 4 ms discrete |
Response time | AOV, AOC 8 ms for analog R1A, R1B, R1C, R2A, R2B 8 ms for discrete |
Linearity error | +/- 0.2 % for output |
Analogue output number | 1 |
Analogue output type | AOC configurable current: 0…20 mA, impedance: 800 Ohm, resolution: 8 bits AOV configurable voltage: 0…10 V, impedance: 470 Ohm, resolution: 8 bits |
Discrete input logic | Logic input not wired (LI1…LI4), < 13 V (state 1) Negative logic (source) (LI1…LI6), > 19 V (state 0) Positive logic (source) (LI1…LI6), < 5 V (state 0), > 11 V (state 1) |
Discrete output number | 2 |
Discrete output type | Configurable relay logic: (R1A, R1B, R1C) 1 NO + 1 NC – 100000 cycles Configurable relay logic: (R2A, R2B) NC – 100000 cycles |
Minimum switching current | R1-R2 10 mA at 5 V DC |
Maximum switching current | R1-R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms R1-R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms R1-R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms R1-R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms |
Discrete input number | 6 |
Discrete input type | (LI1…LI6) programmable at 24 V, 0…100 mA for PLC, impedance: 3500 Ohm |
Acceleration and deceleration ramps | Linear adjustable separately from 0.1 to 999.9 s S, U or customized |
Braking to standstill | By DC injection |
Protection type | Input phase breaks: drive Line supply overvoltage and undervoltage safety circuits: drive Line supply phase loss safety function, for three phases supply: drive Motor phase breaks: drive Overcurrent between output phases and earth (on power up only): drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: motor |
Insulation resistance | >= 500 mOhm 500 V DC for 1 minute |
Local signalling | 1 LED (red) for drive voltage Four 7-segment display units for CANopen bus status |
Time constant | 5 ms for reference change |
Frequency resolution | Analog input: 0.1…100 Hz Display unit: 0.1 Hz |
Connector type | 1 RJ45 for Modbus/CANopen |
Physical interface | RS485 multidrop serial link |
Transmission frame | RTU |
Transmission rate | 10, 20, 50, 125, 250, 500 kbps or 1 Mbps for CANopen 4800, 9600 or 19200 bps for Modbus |
Number of addresses | 1…127 for CANopen 1…247 for Modbus |
Number of drive | 127 for CANopen 31 for Modbus |
Marking | CE |
Operating position | Vertical +/- 10 degree |
Height | 145 mm |
Width | 72 mm |
Depth | 142 mm |
Net weight | 1.5 kg |
Dielectric strength | 2040 V DC between earth and power terminals 2880 V AC between control and power terminals |
---|---|
Electromagnetic compatibility | 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 |
Standards | IEC 61800-5-1 IEC 61800-3 |
Product certifications | C-Tick UL GOST NOM DNV CSA |
pollution degree | 2 |
Protective treatment | TC |
Vibration resistance | 1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 |
Shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3 |
Ambient air temperature for storage | -25…70 °C |
Ambient air temperature for operation | -10…50 °C without derating (with protective cover on top of the drive) -10…60 °C with derating factor (without protective cover on top of the drive) |
Operating altitude | <= 1000 m without derating 1000…2000 m with current derating 1 % per 100 m |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 13.359 cm |
Package 1 Width | 17.149 cm |
Package 1 Length | 18.013 cm |
Package 1 Weight | 1.472 kg |
Unit Type of Package 2 | S06 |
Number of Units in Package 2 | 48 |
Package 2 Height | 73.5 cm |
Package 2 Width | 60 cm |
Package 2 Length | 80 cm |
Package 2 Weight | 85 kg |
Warranty | 18 months |
---|
نقد و بررسیها