Range of product Altivar
Product or component type Variable speed drive
Product specific application Simple machine
Component name ATV11
Application market Asia
Assembly style With heat sink
EMC filter Without EMC filter
Built-in fan With
Network number of phases Single phase
[Us] rated supply voltage 200…240 V – 15…10 %
Supply frequency 50…60 Hz – 5…5 %
Motor power kW 2.2 kW
Line current 24.1 A at 200 V, Isc = 1 kA
Nominal output current 1.4 A 230 V motor 4 kHz
Maximum transient current 15 A for 60 s
Power dissipation in W 97 W at nominal load
Switching frequency 2…16 kHz adjustable
4…16 kHz with derating factor
Braking torque 150 % of nominal motor torque with braking resistor at high inertia
20 % of nominal motor torque without braking resistor at no load
80 % of nominal motor torque with braking resistor at no load
Asynchronous motor control profile Sensorless flux vector control with PWM type motor control signal
Electrical connection Terminal, clamping capacity: 1.5 mm², AWG 14 (AI1, RA-RC, LI1…LI4, DO)
Terminal, clamping capacity: 1.5 mm², AWG 14 (L1, L2, L3, U, V, W, PA, PC)
Supply Internal supply for logic inputs: 15 V (+/- 15 %) 100 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (2.2 to 10 kOhm): 5…5.25 VDC 10 mA, protection type: overload and short-circuit protection
Analogue input type Configurable current AI1 4…20 mA 250 Ohm without adding resistor
Configurable voltage AI1 0…5 V 40000 Ohm only with internal supply
Configurable current AI1 0…20 mA 250 Ohm
Configurable voltage AI1 0…10 V 40000 Ohm
Sampling duration AI1: 20 ms analog
LI1…LI4: 20 ms discrete
Response time 20 ms DO
Linearity error DO: +/- 1 % for output
AI: +/- 5 % for input
Discrete input type Assignable Ll1 forward 5000 Ohm 15 V 24 V
Assignable Ll2 reverse 5000 Ohm 15 V 24 V
Assignable Ll3/Ll4 4 preset speeds 5000 Ohm 15 V 24 V
Discrete input logic Positive logic (source) (LI1…LI4), < 5 V (state 0), > 11 V (state 1)
Logic input not wired (LI1…LI4), < 5 V (state 1)
Negative logic (source) (LI1…LI4), > 11 V (state 0)
Discrete output type Assignable as external voltage DO 30 V max, 30 mA
Assignable as open collector logic output DO 100 Ohm, 50 mA max
Factory set as PWM open collector output DO at 2 kHz 10 mA max
Protected relay logic RA-RC 1 NO
Assignable as internal voltage DO
Minimum switching current RA-RC 10 mA at 24 V DC
Maximum switching current 2 A 250 V AC inductive cos phi = 0.4 7 ms RA-RC
2 A 30 V DC inductive cos phi = 0.4 7 ms RA-RC
5 A 250 V AC resistive cos phi = 1 RA-RC
5 A 30 V DC resistive cos phi = 1 RA-RC
Protection type Line supply overvoltage: drive
Line supply undervoltage: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: motor
Frequency resolution Display unit: 0.1 Hz
Analog input: converter A/D, 10 bits
Electromagnetic compatibility 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to EN/IEC 61000-4-5
Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4
Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3
Maximum motor cable length 20 m with additional EMC filter from 2 to 16 kHz conforming to EN 55011 class A group 1
5 m with additional EMC filter from 2 to 16 kHz conforming to EN 55011 class B
Vibration resistance 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6
1.5 mm peak to peak (f= 3…13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to EN/IEC 60068-2-27
Relative humidity 5…93 % without condensation conforming to IEC 60068-2-3
5…93 % without dripping water conforming to IEC 60068-2-3
Ambient air temperature for operation -10…40 °C without derating
40…50 °C by removing the protective cover from the top of the drive
50…60 °C by removing the protective cover from the top of the drive with current derating of 2.2 % per °C
Operating altitude <= 1000 m without derating
> 1000 m with current derating 1 % per 100 m
Complementary
Product destination Asynchronous motors
Supply voltage limits 170…264 V
Network frequency limits 47.5…63 Hz
Speed drive output frequency 0…200 Hz
Nominal switching frequency 4 kHz
Speed range 1…20
Transient overtorque 150…170 % of nominal motor torque
Regulation loop Factory-set with the speed loop stability and gain
Adjustable frequency
Possible correction for machines with high resistive torque/inertia/fast cycles
Motor slip compensation Adjustable
Preset in factory
Prospective line Isc 1 kA
Output voltage <= 2 x power supply voltage
Insulation Electrical between power and control
Analogue input number 1
Discrete input number 4
Discrete output number 2
Acceleration and deceleration ramps Linear from 0 to 99.9 s
Braking to standstill By DC injection
Insulation resistance > 500 MOhm
Marking CE
Operating position Vertical +/- 10 degree
CAD overall width 117 mm
CAD overall height 142 mm
CAD overall depth 163 mm
Net weight 1.8 kg
Environment
Standards EN 50178
Product certifications CSA
C-Tick
N998
UL
IP degree of protection IP20
Ambient air temperature for storage -25…65 °C
Contractual warranty
Warranty 18 months

توضیحات تکمیلی

نوع:

تک فاز

توان موتور:

2.2KW کاربرد سبک

هیت سینک:

دارد

فیلتر EMC:

ندارد

پنل گرافیکی:

دارد

نرم افزار سازگار:

SoMove

درجه حفاظت:

IP20

کاربرد موتور:

کنترل موتور های آسنکرون

محصول جایگزین:

ATV12

کاتالوگ

https://pishrosanatnovin.com/wp-content/uploads/2025/03/Schneider-Electric_Altivar-11_ATV11HU41M2A.pdf

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “اینورتر تک فاز 2.2 کيلووات اشنایدر ATV11HU41M2A”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

حمل و نقل

همه زمان های تخمینی ارسال علاوه بر زمان های تکمیل است، برای سفارش هایی که قبل از ساعت ۶:۳۰ بعدازظهر انجام می شوند، یک روز کاری بعدی تحویل می دهیم. از شنبه تا پنجشنبه. سفارش هایی که بعد از این ارسال می شوند، ظرف دو روز کاری تحویل داده می شوند. .

Shipping
  • ارسال رایگان بالای 50 میلیون تومان
  • ارسال در سریع ترین زمان با کم ترین هزینه
  • تهران خرید بالای 20 میلیون ارسال رایگان
  • ارسال با پست ، تیپاکس ، باربری و ترمینال

    بازگشت و پرداخت

    ما یک خط مشی بازگشت ۱۴ روزه داریم، به این معنی که شما ۱۴ روز پس از دریافت کالای خود فرصت دارید تا درخواست بازگشت بدهید، برای واجد شرایط بودن برای بازگرداندن، کالای شما باید در همان شرایطی باشد که آن را دریافت کرده اید، استفاده نشده و در اصل آن باشد. بسته بندی. همچنین به تأیید سفارش، شماره سفارش یا مدرک خرید نیاز دارید. پس از دریافت و بازرسی بازگشت شما، به شما اطلاع می دهیم و به شما اطلاع می دهیم که آیا بازپرداخت تأیید شده است یا خیر. در صورت تایید، به صورت خودکار از طریق روش پرداخت اصلی به شما بازپرداخت می شود. لطفاً به یاد داشته باشید که پردازش و ارسال بازپرداخت بانک یا شرکت کارت اعتباری شما نیز ممکن است کمی طول بکشد.برای درخواست بازگشت باید دلیل موجه در مورد جنس یا عدم تایید و یا مغایرت کالای ارسالی با پیش فاکتور ارسالی داشته باشین.

نقد و بررسی‌ها

هنوز بررسی‌ای ثبت نشده است.

اولین کسی باشید که دیدگاهی می نویسد “اینورتر تک فاز 2.2 کيلووات اشنایدر ATV11HU41M2A”

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *