بی متال 28 تا 115 آمپر اشنایدر LR9G115
بی متال 28 تا 115 آمپر اشنایدر LR9G115
Range | TeSys |
---|---|
product name | TeSys LRG |
Product or Component Type | Electronic thermal overload relay |
Device short name | LR9G |
Relay application | Motor protection |
network type | AC |
Thermal overload class | Class 5E…30E IEC 60947-4-1 |
Thermal protection adjustment range | 28…115 A |
Network Frequency | 30…60 Hz 100 Hz |
---|---|
overvoltage category | III |
Tripping threshold | 1.125 +/- 0.07 In IEC 60947-4-1 |
Protection type | Ground fault protection 0…1 s – alarm circuit IEC 60947-4-1 Ground fault protection 0…1 s – alarm circuit UL 60947-4-1 Phase loss 0…4 s – alarm circuit Phase imbalance 0…5 s – alarm circuit IEC 60947-4-1 Phase imbalance 0…5 s – alarm circuit UL 60947-4-1 |
Local signalling | LED Trip indicator |
Contacts type and composition | 1 NO + 1 NC |
[Ith] conventional free air thermal current | 5 A |
[Uc] control circuit voltage | 24…500 V AC 50/60 Hz 24…250 V DC |
[Ue] rated operational voltage | 1000 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 8 kV |
Reset | Automatic reset Manual |
Mechanical durability | 7000 cycles |
Surge withstand | 4 kV |
Electromagnetic compatibility | EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference – test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47 |
Connections – terminals | Power circuit: bar – busbar cross section: 25 x 6 mm Power circuit: lugs-ring terminals 1 0.3 in² (185 mm²) Control circuit: push-in 1 0.0003…0.004 in² (0.2…2.5 mm²) – cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.0004…0.004 in² (0.25…2.5 mm²) – cable stiffness: flexible with cable end Control circuit: push-in 2 0.0008…0.002 in² (0.5…1.0 mm²) with cable end |
Tightening torque | 18 N.m |
Mounting support | Direct on contactor Plate |
Standards | EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ UL 60335-1 |
Product Certifications | CB Scheme CCC cULus UKCA ATEX EU-RO-MR by DNV-GL EAC |
IP degree of protection | IP2X front face with shrouds IEC 60529 IP2X front face with shrouds VDE 0106 |
---|---|
Protective treatment | TH |
Ambient air temperature for operation | -13…140 °F (-25…60 °C) |
Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) |
Permissible ambient air temperature around the device | -40…140 °F (-40…60 °C) at Uc |
Adjustment of dial setting | -13…140 °F (-25…60 °C) |
Mechanical robustness | Vibrations 5…300 Hz 6 gn contactor open Shocks 15 gn 11 ms contactor closed |
Height | 4.2 in (107 mm) |
Width | 4.1 in (105 mm) |
Depth | 5.0 in (126 mm) |
Net Weight | 1.8 lb(US) (0.8 kg) |
color | Dark grey |
Category | US10I1222330 |
---|---|
Discount Schedule | 0I12 |
GTIN | 3606481920270 |
Returnability | Yes |
Country of origin | FR |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 6.69 in (17.000 cm) |
Package 1 Width | 7.87 in (20.000 cm) |
Package 1 Length | 8.27 in (21.000 cm) |
Package 1 Weight | 3.122 lb(US) (1.416 kg) |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 2 |
Package 2 Height | 11.81 in (30.000 cm) |
Package 2 Width | 11.81 in (30.000 cm) |
Package 2 Length | 15.75 in (40.000 cm) |
Package 2 Weight | 7.562 lb(US) (3.430 kg) |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 16 |
Package 3 Height | 29.53 in (75.000 cm) |
Package 3 Width | 23.62 in (60.000 cm) |
Package 3 Length | 31.50 in (80.000 cm) |
Package 3 Weight | 78.264 lb(US) (35.500 kg) |